• <samp id="ce0ma"><tfoot id="ce0ma"></tfoot></samp>
    <strike id="ce0ma"><s id="ce0ma"></s></strike><ul id="ce0ma"></ul>
    <strike id="ce0ma"></strike>
      <strike id="ce0ma"><menu id="ce0ma"></menu></strike>
    • <th id="ce0ma"><s id="ce0ma"></s></th>
      產(chǎn)品展示
      PRODUCT DISPLAY

      打印當(dāng)前頁(yè)

      免費(fèi)咨詢(xún):021-67610176

      發(fā)郵件給我們:market@hsiyen.cn

      分享到:
      產(chǎn)品展示您現(xiàn)在的位置: 首頁(yè) > 產(chǎn)品展示 > > 美國(guó)戴安Dionex > 072929美國(guó)戴安Dionex Acclaim Carbamate LC Column 液相色譜柱

      美國(guó)戴安Dionex Acclaim Carbamate LC Column 液相色譜柱

      簡(jiǎn)要描述:

      戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢(shì)和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。   
      戴安公司的快速溶劑萃取儀15分鐘之內(nèi)僅用15毫升溶劑既可完成對(duì)10g樣品的萃取,該技術(shù)已在環(huán)境、藥物、食品和聚合物工業(yè)等領(lǐng)域得到廣泛應(yīng)用。

      型號(hào) 072929
      廠商性質(zhì) 代理商
      更新日期 2017-10-28

      美國(guó)戴安Dionex Acclaim Carbamate LC Column 液相色譜柱

      Acclaim Carbamate LC Column 

      The Acclaim Carbamate column is designed for baseline separation of carbamates (N-methylcarbamate and N-methylcarbamoyloxime pesticides) specified in US EPA Method 531.2. Carbamate pesticides are widely used throughout the world. Drinking water and raw surface water is monitored for the presence of carbamate pesticides and related compounds using an established EPA Method 531.2 that uses HPLC with postcolumn derivatization. LC-MS is the method of choice for the ultimate sensitivity.

      • Baseline separation of carbamate pesticides specified in US EPA Method 531.2
      • Use with either LC/postcolumn derivatization/fluorescence or LC/MS detection.
      • Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) phase gradients.
      • High efficiency, extremely low column bleed, and rugged column packing

      Acclaim Carbamate columns are available in a variety of column formats: The 5 ?m, 4.6 × 250 mm column sets the standard for the highest resolution with postcolumn reaction (PCR) and fluorescence detection (FLD); the 3 ?m, 4.6 × 150 mm column saves time and increases sample throughput; the 3 ?m, 3.0 × 150 mm column saves time and reduces solvent consumption; and the 3 ?m, 2.1 × 150 mm column is for LC/MS, to achieve the lowest possible detection limits. Two RSLC, 2.2 ?m columns are available for high-resolution, high-throughput separations:  2.1 × 100 mm and 2.1 × 150 mm.

      技術(shù)參數(shù):


      Acclaim Carbamate Column Specifications
      Column chemistryProprietary alkyl group
      Operating pressure limit (recommended)6000 psi (4000 psi)
      Operating pH range (recommended)2.5–8.0 (3.0–7.0)
      Operating flow rate range (recommended)0.5–3.0 (0.8–1.6) mL/min for 4.6 mm i.d. formats
      0.3–1.5 (0.4–0.8) mL/min for 3.0 mm i.d. formats
      0.15–0.80 (0.2–0.4) mL/min for 2.1 mm i.d. formats
      訂購(gòu)信息:

      Analytical Columns
      Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 150mm)075596
      Acclaim RSLC Carbamate, 2.2?m Analytical (2.1 x 100mm)075597
      Acclaim Carbamate, 5?m Analytical (4.6 x 250mm)072924
      Acclaim Carbamate, 3?m Analytical (4.6 x 150mm)072925
      Acclaim Carbamate, 3?m Analytical (3.0 x 150mm)072926
      Acclaim Carbamate, 3?m Analytical (2.1 x 150mm)072927
      Guard Columns
      Acclaim Carbamate, 3?m Guard (4.6 x 10mm) 2ea (Use Holder V-2)072928
      Acclaim Carbamate, 3?m Guard (3.0 x 10mm) 2ea (Use Holder V-2)072929
      Acclaim Carbamate, 3?m Guard (2.1 x 10mm) 2ea (Use Holder V-2)072930
      Acclaim SST Guard Cartridge Holder V-2069580
      Acclaim Guard Kit (Holder and coupler) V-2069707
      Guard to Analytical Column Coupler V-2074188

      留言框

      • 產(chǎn)品:

      • 您的單位:

      • 您的姓名:

      • 聯(lián)系電話:

      • 常用郵箱:

      • 省份:

      • 詳細(xì)地址:

      • 補(bǔ)充說(shuō)明:

      • 驗(yàn)證碼:

        請(qǐng)輸入計(jì)算結(jié)果(填寫(xiě)阿拉伯?dāng)?shù)字),如:三加四=7