戴安公司生產(chǎn)的儀器主要有離子色譜儀、高效液相色譜儀、快速溶劑萃取儀和氨基酸直接分析儀。其中離子色譜儀憑借著雄厚的技術(shù)優(yōu)勢(shì)和方法已廣泛地應(yīng)用于各個(gè)領(lǐng)域,其*達(dá)80%。與離子色譜相關(guān)的文章有90%均出自戴安公司生產(chǎn)的離子色譜儀。 戴安公司的快速溶劑萃取儀15分鐘之內(nèi)僅用15毫升溶劑既可完成對(duì)10g樣品的萃取,該技術(shù)已在環(huán)境、藥物、食品和聚合物工業(yè)等領(lǐng)域得到廣泛應(yīng)用。
型號(hào) | 美國(guó)戴安 P/N: 052244 |
---|---|
廠商性質(zhì) | 代理商 |
更新日期 | 2018-04-16 |
Specifically designed for trace bromate in drinking water, the Thermo Scientific? Dionex? IonPac? AS9-HC column is the specified column for U.S EPA Methods 300.1 and 317.0.
The Dionex IonPac AS9-HC column is a high-capacity carbonate eluent anion-exchange column with selectivity similar to the Dionex IonPac AS9-SC column. The Dionex IonPac AS9-HC column also supports the analysis of oxyhalides and inorganic anions, including fluoride, chlorite, bromate, chloride, nitrite, bromide, chlorate, nitrate, phosphate, and sulfate. The Dionex IonPac AS9-HC column is specified in validated methods such as U.S. EPA Method 300.1 and 317.0 and meets or exceeds the performance requirements of these methods.
This column separates trace bromate in drinking water matrices using an isocratic carbonate eluent and a large-loop injection. The Dionex IonPac AS9-HC column also offers good retention of fluoride out of the water dip. The column’s high capacity (190 μeq for 4 × 250 mm column) increases retention time to approximay 22 min. Use the Thermo Scientific Dionex Anion Electrolytically Regenerating Suppressor (AERS 500) with the Dionex IonPac AS9-HC column.
The Dionex IonPac AS9-HC column is offered in three formats: standard bore (4 × 250 mm), microbore (2 × 250 mm), and capillary (0.4 × 250 mm). The capillary format is packed with the same material as the equivalent standard bore version (providing the same performance as a 4 mm column), but requires only 1/100th the eluent flow rate. The capillary format provides the advantage of significantly reduced eluent consumption with helps reduce the operating costs.
Note: The Thermo Scientific Dionex IonPac AS23 column is the newest carbonate eluent column recommended for the analysis of oxyhalides including bromate.
Thermo Scientific Dionex IonPac AS9-HC Anion-Exchange Column Specifications | |
---|---|
Dimensions | Dionex IonPac AS9-HC Analytical Column: 2 × 250 and 4 × 250 mm Dionex IonPac AS9-HC Capillary Column: 0.4 × 250 mm Dionex IonPac AG9-HC Guard Column: 2 × 50 mm and 4 × 50 mm Dionex IonPac AG9-HC Capillary Guard Column: 0.4 × 50 mm |
Phase Compatibility | pH 0–12; 0–100% HPLC solvents |
Substrate Characteristics | Bead Diameter: 9.0 ?m Pore Size: 2000 ? Cross-Linking (%DVB): 55% |
Latex Characteristics | Functional Group: Alkyl/alkanol quaternary ammonium ion Latex Cross-Linking: 15% Latex Diameter: 90 nm Hydrophobicity: Medium-Low |
Maximum Operating Pressure | 4000 psi |
Capacity | 1.9 ?eq (0.4 × 250 mm capillary column) 47.5 ?eq (2 × 250 mm analytical column) 190 ?eq (4 × 250 mm analytical column) 0.06 ?eq (0.4 × 50 mm capillary guard column) 1.5 ?eq (2 × 50 mm guard column) 6 ?eq (4 × 50 mm guard column) |
Column Construction | PEEK? with 10-32 threaded ferrule-style end fittings. All components are nonmetallic. |
Analytical Columns | |
---|---|
IonPac AS9-HC Analytical Column (4 x 250 mm) | 051786 |
IonPac AS9-HC Analytical Column (2 x 250 mm) | 052244 |
Dionex IonPac AS9-HC Capillary Column (0.4 × 250 mm) | 082319 |
Guard Columns | |
---|---|
IonPac AG9-HC Guard Column (4 x 50 mm) | 051791 |
IonPac AG9-HC Guard Column (2 x 50 mm) | 052248 |
Dionex IonPac AG9-HC Capillary Column (0.4 × 50 mm) | 088296 |